C215 Acceleration Data Scaling Error加速度數據縮放誤差
Cause:原因:
The display format of the acceleration data can be set with the help of the
scaling parameter.
加速度數據的顯示格式可以通過縮放參數。
The internal drive format of the acceleration data is dependent on the applied feedback and the controller resolution.
加速度數據的內部驅動格式取決于所施加的反饋和控制器分辨率。
The factor for the conversion of the acceleration data from the internal drive format into the display format (or the reverse process) is outside of the
workable area.
將加速度數據從內部驅動格式轉換為顯示格式(或反向過程)的因素不在可行區域。
Remedy:補救措施:
Connect the drive with a PC and start DriveTop.
將硬盤與電腦連接,然后啟動DriveTop。
In the dialog box „Scaling/Mechanical system" select a scaling setting.
在“縮放/機械系統”對話框中,選擇縮放設置。
Should another scaling installation other than one from DriveTop be used,
then the following parameters must be checked.
如果使用DriveTop以外的其他縮放安裝,則必須檢查以下參數。
• S-0-0160, Acceleration Data Scaling Type
S-0-0160,加速度數據縮放類型
• S-0-0161, Acceleration Data Scaling Factor
S-0-0161,加速度數據比例因子
• S-0-0162, Acceleration Data Scaling Exponent
S-0-0162,加速度數據標度指數
• S-0-0121, Input Revolutions of Load Gear
S-0-0121,負載齒輪的輸入轉數
• S-0-0122, Output Revolutions of Load Gear
S-0-0122,負載齒輪的輸出轉數
• S-0-0123, Feed Constant
S-0-0123,進料常數